Power Cable Reference

CableODOhmsAMPSVolts
RG1420.195″507A1900V
RG8A/U0.405″508A5000V
RG393/U0.390″5010A5000V
RG16750.246″5014A2900V
CableInsulatorTempConductor ODRF/DC Recommended Max Power
RG142TFE-55 to +200 °C0.037″
Solid
500RF
1000DC
RG8A/UPolyethylene-40 to +80 °C0.0855″
Stranded 7x
500RF
5000DC
RG393/UTFE-55 to +200 °C0.0936″
Stranded 7x
1000RF
7000DC
RG1675TFE-70 to +200 °C0.065″
Solid
1500RF
9000DC

 

The maximum continuous current rating for an electronic cable is limited by center conductor size, number of conductors contained within the cable, maximum temperature rating of the cable, and environmental conditions such as ambient temperature and air flow.

The recommended power is to be used as a guide. Other process variables, such as cable length, operating temperature, and duty cycle, can greatly effect ratings. Please consult Angstrom Sciences, Inc. for further recommendations.